Checking the analog input unit (Standard mode)
If the AI8 input unit is correctly connected to the engine, the INPUT UNIT ID indicator of the AI8 will show the ID
number of that unit (i.e., the number of the INPUT connector on the engine to which the AI8 is connected).
If the AI8 connections or word clock synchroniza
-
tion are faulty, one of the following error displays
will appear in the INPUT UNIT ID indicator.
E1
........................The AI8 is connected to an
OUTPUT connector of the
engine. Re-connect it to an
INPUT connector.
E3
........................Either the cable connected to the
OUTPUT connector of the AI8
rear panel is disconnected, or the
connection destination is incor-
rect. Please check the cable.
UL (unlocked)
....The word clock of the AI8 is not
synchronized with the PM1D
system.
Check the connection for the
WORD CLOCK IN connector of
the AI8, or the CS1D word clock
settings (
p.24).
UC (unconnected)
Control signals are not being
received correctly. Make sure
that the engine is powered-on.
INPUT UNIT NO.
PHANTOM MASTER
ON
OFF
+48V
POWER
ON/ OFF
12345 678
ANALOG INPUT BOX
INPUT UNIT ID
ID number of the AI8
(when the AI8 is connected to the
INPUT 1 connector of the engine)