User Manual

Global functions
50
OUTPUT UNIT
[Function]
Displays the type of card that is connected to the output unit. You can also use this screen to make virtual con-
nections for output units and cards.
Console
In the LCD FUNCTION
ACCESS block, press the [SYS/
W.CLOCK] switch (press repeat-
edly until the screen shown at the
right appears)
Display
MENU button SYS/
W.CLOCK button OUTPUT
UNIT tab
[Screen functions]
1 Selected unit
This displays the status of the currently selected out-
put unit.
The types of I/O card installed in that unit will be
shown by graphics.
When you select a card, the status of that card will be
displayed in the card settings window (6). The
selected card will be displayed with green shading.
The card will be displayed with shading if it is not
installed correctly, or if it is a card that cannot be
controlled.
2 OUT1–OUT6 buttons
The output unit displayed in 1 can be selected by
number using these buttons. When editing off-line,
you can select DSP1D-EX {DSP1D} INPUT jacks for
virtual connection to output units.
The output unit connected to [OUTPUT] connector
1 of the DSP1D-EX will be displayed as “OUT1, the
output unit connected to [OUTPUT] connector 2 as
OUT2, and so forth. The number of the currently
selected unit is indicated by the graphic in the screen.
1 3
4
2