User Manual

Global functions
60
Output metering
[Function]
Display the output levels of MIX channels 1–48, MATRIX channels 1–24, STEREO A/B channels, MONITOR
OUT jacks A/B, and CUE OUT jacks. The location at which the output levels are measured can also be
selected.
Console
In the LCD FUNCTION ACCESS
block, press the [METER] switch
(press repeatedly until the screen
shown at the right appears)
Display
MENU button METER button
tab for the desired channel
[Screen functions]
1 Meters
These are peak level meters that show the output lev-
els from the various channels and output jacks.
The current master level is shown in the number box
located below.
The and CLIP meter will light if clipping occurs at
a metering point, PRE EQ, POST EQ, POST COMP,
or INSERT IN point in the currently selected chan-
nel.
However, the MONITOR A/B CUE meter does not
have a or CLIP indicator.
2 Pairing icon
This shows the channel number and the pairing status.
By clicking this area, you can set/defeat pairing.
3 METERING POINT
You can pre-specify metering points for PRE and
POST, and then use the PRE button and POST but-
ton to switch between the two selected metering
points.
The following metering points can be selected for
each.
PRE button
PRE EQ .............. Immediately before the EQ
PRE FADER....... Immediately before the fader
POST button
POST FADER .... Immediately after the fader
POST ON........... After the [ON] switch
1
2
4
3