User Manual
Global functions
60
Output metering
[Function]
Display the output levels of MIX channels 1–48, MATRIX channels 1–24, STEREO A/B channels, MONITOR
OUT jacks A/B, and CUE OUT jacks. The location at which the output levels are measured can also be
selected.
■ Console
In the LCD FUNCTION ACCESS
block, press the [METER] switch
(press repeatedly until the screen
shown at the right appears)
■ Display
MENU button → METER button
→ tab for the desired channel
[Screen functions]
1 Meters
These are peak level meters that show the output lev-
els from the various channels and output jacks.
The current master level is shown in the number box
located below.
The ∑ and CLIP meter will light if clipping occurs at
a metering point, PRE EQ, POST EQ, POST COMP,
or INSERT IN point in the currently selected chan-
nel.
However, the MONITOR A/B CUE meter does not
have a ∑ or CLIP indicator.
2 Pairing icon
This shows the channel number and the pairing status.
By clicking this area, you can set/defeat pairing.
3 METERING POINT
You can pre-specify metering points for PRE and
POST, and then use the PRE button and POST but-
ton to switch between the two selected metering
points.
The following metering points can be selected for
each.
PRE button
• PRE EQ .............. Immediately before the EQ
• PRE FADER....... Immediately before the fader
POST button
• POST FADER .... Immediately after the fader
• POST ON........... After the [ON] switch
1
2
4
3