User Manual

Global functions
64
OSCILLATOR
[Function]
Switch the internal oscillator on/off, and select its assignment destination. The internal oscillator can be used
to measure the acoustical response of the concert hall, or to match levels with external devices.
Console
In the LCD FUNCTION ACCESS
block, press the [MON/CUE] switch
(press repeatedly until the screen
shown at the right appears)
Display
MENU button MON/CUE but-
ton OSCILLATOR tab
[Screen functions]
1 Level meter
This level meter shows the output level of the oscilla-
tor.
2 OSC LEVEL (oscillator output level)
This knob adjusts the output level of the oscillator.
The range is from – 96 – 0 dB.
3 OSC ON/OFF (oscillator on/off)
This is an on/off switch for the oscillator.
This switch is linked with the [OSC ON] switch
located on the CS1D top panel.
4 OSC OUT
In this section you can patch the oscillator signal to a
physical output jack for direct output.
When you click button, the OSC DIRECT OUT
popup window will appear, in which you can select
the jack for direct output.
You can also use the ON/OFF button to switch the
direct output on/off. (The ON/OFF button is linked
with the [OSC OUT] switch located on the CS1D top
panel.)
2
1
4
3