User Manual

Input functions
148
IN DELAY functions
Make settings for individual input channel delay
CH 1–24 – CH 72-96/ST IN 1-8
[Functions]
Make delay settings for each input channel.
Console
In the LCD FUNCTION ACCESS
block, press the INPUT [DELAY]
switch (Press repeatedly until the
desired input channel appears.)
Display
MENU button INPUT DELAY
button The tab corresponding to
the desired input channel
[Screen functions]
1 DELAY SCALE
Select the desired unit of delay time. The unit you
select here will be used in the numerical box below
the delay time setting knob (3).
The units you select here are linked with the OUT
DELAY function DELAY SCALE setting. If you
change the selected units, your selection will be
reflected by the delay time display in other screens.
METER
The delay time will be displayed as a distance (in
meters), calculated by the speed of sound (
343.59 m/s
in an air temperature of 20°C) × the delay time (in
seconds).
FEET
The delay time will be displayed as a distance (in
feet), calculated by the speed of sound (1127.26 feet/s
in an air temperature of 20°C) × the delay time (in
seconds).
SAMPLE (number of samples)
The delay time will be displayed in samples. If you
change the clock rate (displayed immediately below
the button) at which the PM1D system is operating,
the number of samples will change accordingly.
1