Initializing the PM5D’s internal memory
If an error occurs in the PM5D’s internal memory, or if you are unable to return to normal operation because you have for-
gotten the system password, use the following procedure to initialize the internal memory.
All of the content that had been saved in memory will be lost if
you initialize the internal memory. You must use extreme cau-
tion when performing this operation.
1
While holding down the SCENE MEMORY
[STORE] key of the panel, turn on the power of
the PW800W power supply.
After the opening screen, the following initialization
menu screen will appear.
2
Click one of the following buttons to select the
desired type of initialization.
INITIALIZE ALL MEMORIES
All memories including scene memories and libraries
will return to their factory-set condition.
INITIALIZE CURRENT MEMORIES
Memories other than scene memories and libraries will
return to their factory-set condition.
CANCEL
The initialization procedure will be aborted, and the
PM5D will start up in normal operating mode.
Note
Note
If the voltage of the backup battery runs low, or if an error
occurs in the internal memory, a warning message will appear
at the bottom of the screen, and the initialization menu will
appear “by force.” Please note that if the warning message is
displayed, and you click the CANCEL button to start in normal
operating mode, we cannot guarantee that the system will
operate correctly.
3
A message will ask you to confirm that you
really want to initialize; click the OK button.
When the internal memory has been initialized, the
PM5D will start up in normal operating mode.
Adjusting the faders and input/output gain (Calibration)
Depending on the conditions of use, discrepancies may occur in the behavior of the motor faders. you can use the Calibration
function to correct such discrepancies. If necessary, you can also make fine adjustments to the analog input/output gain.
1
While holding down the [ENTER] key of the
panel, turn on the power of the PW800W
power supply.
After the opening screen, the following calibration
menu screen will appear.
2
Click one of the following buttons to choose
what you want to calibrate.
A window for the calibration item you selected will
appear.
3
Make calibration settings as directed by the
instructions that appear in the window.
4
Click the OK button in the window.
The calibration settings will be applied, and the PM5D
will start up in normal mode.
CALIBRATE FADER
POSITION
The FADER CALIBRATION win-
dow will appear, allowing you to
calibrate the specified faders.
CALIBRATE AD INPUT
GAIN (make fine adjust-
ments to the analog
input gain; PM5D-RH
model only)
The AD INPUT TRIM window
will appear, allowing you to
make fine adjustments to the
gain of the specified analog
input port.
CALIBRATE OUTPUT
GAIN (make fine adjust-
ments to the output
ports)
The OUTPUT TRIM window will
appear, allowing you to make
fine adjustments to the gain of
the specified output port.