User`s guide

MIDI Setup 81
ProMix 01 User’s Guide
1. Press [MIDI].
The MIDI menu appears.
2. Select MIDI SETUP and
press [ENTER].
The MIDI SETUP LCD function
appears.
3. Use the cursor buttons to
select parameters and the
PARAMETER wheel to set
them.
Tx, Rx, OMNI, and ECHO
parameters can also be set
using [ENTER].
4. To exit this function and
return to the MIDI menu,
select EXIT and press
[ENTER], or just press
[MIDI].
The MIDI menu reappears.
MIDI Setup
The MIDI SETUP LCD function shown below is used to set basic
MIDI parameters.
The parameters are:
Tx Ch — this determines which MIDI Channel ProMix 01 uses to
transmit Program Change, Control Change, and Bulk Dump mes-
sages. MIDI Channels 1 through 16 can be selected.
Rx Ch — this determines which MIDI Channel ProMix 01 uses to
receive Program Change, Control Change, and Bulk Dump messages.
MIDI Channels 1 through 16 can be selected.
The following parameters can be set independently for Program
Change (PROGRAM), Control Change (CONTROL), and Bulk
Dump (BULK).
Tx — this determines whether ProMix 01 transmits MIDI data.
When set to ON, MIDI data is transmitted as normal. When set to
OFF, no MIDI data is transmitted.
Rx — this determines whether ProMix 01 receives MIDI data. When
set to ON, MIDI data is received as normal. When set to OFF, received
MIDI data is ignored.
OMNI — this determines whether ProMix 01 receives MIDI data on
all MIDI Channels. When set to OFF, MIDI data is received on the
MIDI Channels specified using Rx Ch. When set to ON, however,
MIDI data is received on all MIDI Channels, regardless of Rx Ch set-
tings.
ECHO — this determines whether MIDI data received at MIDI IN is
echoed through to MIDI OUT. When set to OFF, data is not echoed.
When set to ON, it is echoed.
Note: In Channel mode, Control Changes are transmitted and received
on several MIDI Channels. See “Control Change” on page 83.