User`s guide

90 Chapter 10: Other Functions
ProMix 01 User’s Guide
1. Press [UTILITY].
The UTILITY menu appears.
2. Select OSCILLATOR and
press [ENTER].
The OSCILLATOR LCD func-
tion appears.
3. Assign the oscillator.
4. Turn the OSC ON.
5. Set the frequency (FREQ).
6. Set the level.
7. To exit this function and
return to the UTILITY menu,
select EXIT and press
[ENTER], or just press [UTIL-
ITY].
The UTILITY menu reappears.
Using the Oscillator
ProMix 01 features a useful sine wave oscillator that can be assigned
to SEND3, SEND4, and the stereo output. Since its digital, it is highly
accurate and produces a very clean sine wave. It can also produce pink
noise. You can use it when setting recording levels on multitrack, two
track, cassette, and DAT recorders. It’s also useful for system trouble-
shooting and other studio tasks.
Shown below is the OSCILLATOR LCD function. Oscillator param-
eters appear to the left of the LEVEL fader, and level meters for
SEND3, SEND4, and ST OUT to the right.
The parameters are:
ASSIGN — use these parameters to assign the oscillator to SEND3,
SEND4, and the stereo output (ST OUT).
OSC — use this parameter to turn the oscillator ON and OFF. This
is automatically set to OFF when another LCD function is selected.
FREQ — use this parameter to select a sine wave frequency: 100Hz,
1kHz, 10kHz, or PINK noise.
LEVEL — use this parameter to set the oscillator level. The fader
graphic indicates the level setting. The fader knob changes, too.
Note: Before turning the oscillator ON, it’s a good idea to set the SEND3,
SEND4, or ST OUT faders to a minimal level. This will prevent any sud-
den tone burst surprises in your monitors or foldback headphones.
LEVEL = –dB LEVEL = 0dB Other levels