User Manual
Table Of Contents
- Introduction
- Audio Components
- The Difference Between Mono, Stereo, and Multi
- How to Control Control Signals
- Acoustic Echo Canceller (AEC)
- Ambient Noise Compensator (ANC)
- Audio Detector
- Auto Gain Control (AGC)
- Combiner
- Room Combiner/Room Combiner plus Automixer
- ■ “Room Combiner” component editor/”Room Combiner plus Automixer” component editor
- ■ “Room Combiner” component editor/”Room Combiner plus Automixer” component editor
- Combiner parameter setting window (Room Combiner)
- Combiner parameter setting window (Room Combiner plus Automixer)
- Control
- Control
- Dugan Automixer window (Room Combiner plus Automixer)
- Room Combiner/Room Combiner plus Automixer
- DCA
- Delay
- Dynamics
- REV-X
- EQ
- Fader
- Feedback Suppressor
- Filter
- Input/Output
- Meter
- Mixer
- Oscillator
- Polarity
- Probe
- Router
- Source Selector
- Speaker Processor
- Control Components
- Control Methods for Control Components
- Trigger
- Button (Normalized Value)
- Button (Value)
- Radio Button (Normalized Value)
- Radio Button (Value)
- Fader (Normalized Value)
- Fader (Value)
- Processing
- Logic (Normalized Value)
- NOT (Normalized Value)
- Flip-Flop (Normalized Value)
- Invert (Normalized Value)
- Compare (Normalized Value)
- Difference (Normalized Value)
- Max/Min (Normalized Value)
- Negate (Value)
- Compare (Value)
- Multi Compare (Value)
- Difference (Value)
- Max/Min (Value)
- Delay
- External Events
- Suspend
- Router
- Other
- GPI In
- GPI Out
ProVisionaire Design DME7 Component Guide
134
If any 1 of the inputs is 0, then the output is 1.
If the input and output are 0, the indicator is off, and if the input and output are 1, the
indicator is on.
■ ”Logic” component editor (OR)
When all of the inputs are 0, then the output is 0.
If any 1 of the inputs is 1, then the output is 1.
If the input and output are 0, the indicator is off, and if the input and output are 1, the
indicator is on.
■ ”Logic” component editor (NOR)
When all of the inputs are 0, then the output is 1.
If any 1 of the inputs is 1, then the output is 0.
If the input and output are 0, the indicator is off, and if the input and output are 1, the
indicator is on.
■ ”Logic” component editor (XOR)
When the number of 1 inputs is odd, the output is 1.
When the number of 1 inputs is even, the output is 0.
If the input and output are 0, the indicator is off, and if the input and output are 1, the
indicator is on.
■ ”Logic” component editor (NOT XOR)
When the number of 1 inputs is even, the output is 1.
When the number of 1 inputs is odd, the output is 0.
If the input and output are 0, the indicator is off, and if the input and output are 1, the
indicator is on.
■ ”Logic” component editor (1 of N)
If any 1 of the inputs is 1, then the output is 1.
If any 2 or more of the inputs are 1, then the output is 0.
If the input and output are 0, the indicator is off, and if the input and output are 1, the
indicator is on.