User Manual
Table Of Contents
- Introduction
- Audio Components
- The Difference Between Mono, Stereo, and Multi
- How to Control Control Signals
- Acoustic Echo Canceller (AEC)
- Ambient Noise Compensator (ANC)
- Audio Detector
- Auto Gain Control (AGC)
- Combiner
- Room Combiner/Room Combiner plus Automixer
- ■ “Room Combiner” component editor/”Room Combiner plus Automixer” component editor
- ■ “Room Combiner” component editor/”Room Combiner plus Automixer” component editor
- Combiner parameter setting window (Room Combiner)
- Combiner parameter setting window (Room Combiner plus Automixer)
- Control
- Control
- Dugan Automixer window (Room Combiner plus Automixer)
- Room Combiner/Room Combiner plus Automixer
- DCA
- Delay
- Dynamics
- REV-X
- EQ
- Fader
- Feedback Suppressor
- Filter
- Input/Output
- Meter
- Mixer
- Oscillator
- Polarity
- Probe
- Router
- Source Selector
- Speaker Processor
- Control Components
- Control Methods for Control Components
- Trigger
- Button (Normalized Value)
- Button (Value)
- Radio Button (Normalized Value)
- Radio Button (Value)
- Fader (Normalized Value)
- Fader (Value)
- Processing
- Logic (Normalized Value)
- NOT (Normalized Value)
- Flip-Flop (Normalized Value)
- Invert (Normalized Value)
- Compare (Normalized Value)
- Difference (Normalized Value)
- Max/Min (Normalized Value)
- Negate (Value)
- Compare (Value)
- Multi Compare (Value)
- Difference (Value)
- Max/Min (Value)
- Delay
- External Events
- Suspend
- Router
- Other
- GPI In
- GPI Out
ProVisionaire Design DME7 Component Guide
137
Flip-Flop (Normalized Value)
This component is used to enable toggle operation.
INPUT
Set: Trigger input to push the [Set] button*
Reset: Trigger input to push the [Reset] button*
Toggle: Trigger input to push the [Toggle] button*
*: Values that are input from an external source act as simple triggers that are not related to
any operation.
OUTPUT
Out: on/off state of the [Set] button (OFF:0, ON:1)
Not Out: Out inversion value
When the [Set] button is on, 1 is output from Out, and the Out inversion value is output from
Not Out.
When the [Reset] button is turned on, the [Set] button is turned off.
■ ”Flip-Flop” component editor
① When the [Set] button is turned on, the [Toggle] button also turns on, and the [Output]
indicator turns on.
② When the [Reset] button is turned on, the [Toggle] button turns off, and the [Output]
indicator turns off. 0 is output from Out, and 1 is output from Not Out.
③ When the [Toggle] button is pressed, it switches between on or off. When it is on, the [Set]
button runs the on process, and when it is off, the [Reset] button runs the on process.