e [LOCAL IN]
Adjusts the send amount from LOCAL IN to ROOM OUT, and turns mute on/off.
f [BGM]
Selects one of BGM1 to 4, adjusts the amount of that BGM that is sent to Room Out, and
turns mute on/off.
g [ROOM OUT]
Adjusts the ROOM OUT level and turns mute on/off.
Control
Room Combiner
Parameter types of the input/output values for each Port
Input Value
Control Parameter Output Value
Type Range
Input Port Name Parameter Range
Output Port Name Type Range
Value
Num
0,1
Combine 1+2 OFF:0, ON:1
Combine 1+2 Value
Num
OFF:0,
ON:1
Value
dB
−∞
10.00
RoomIn Level Room1 −∞10.00
RoomIn Level Room1 Value
dB
−∞
10.00
Normalized
0.00
1.00
Value
Num
0,1
RoomIn On Room1 OFF:0, ON:1
RoomIn On Room1 Value
Num
OFF:0,
ON:1
Value
dB
−∞
10.00
Paging Level Room1 −∞10.00
Paging Level Room1 Value
dB
−∞
10.00
Normalized
0.00
1.00
Value
Num
0,1
Paging On Room1 OFF:0, ON:1
Paging On Room1 Value
Num
OFF:0,
ON:1
Value
Num
0,1,2,3
BGM Room1
0:BGM1,1:BGM2,2:BGM3,3:BGM4
BGM Room1 Value
Num
BGM1:0 BGM2:1
BGM3:2 BGM4:3
Value
dB
−∞
10.00
BGM Level Room1 −∞10.00
BGM Level Room1
Value
Num
OFF:0,
ON:1
Normalized
0.00
1.00
Value
Num
0,1
BGM On Room1 OFF:0, ON:1
BGM On Room1 Value
Num
OFF:0,
ON:1
Value
dB
−∞
10.00
RoomOut Level Room1
−∞10.00
RoomOut Level Room1
Value
dB
−∞
10.00
Normalized
0.00
1.00
Value
Num
0,1
RoomOut On Room1 OFF:0, ON:1
RoomOut On Room1 Value
Num
OFF:0,
ON:1