User Manual

Table Of Contents
ProVisionaire Design DME7 Component Guide
50
a
Limiter [ON] button
Switches the limiter function between enabled and disabled.
b Limiter curve
This shows the effect as a graph. The horizontal axis is the input signal level, and the
vertical axis is the output signal level.
c [GR] meter
Indicates the amount of gain reduction.
d [KEY IN] list box
From this list, select the input signal that is used as the key-in signal; that is, the reference
signal that causes the limiter to operate.
The following choices are provided.
[Self]
For a monaural channel component, the input signal is used as the trigger source.
[L]
For a stereo channel component, the L input signal is used as the trigger source.
[R]
For a stereo channel component, the R input signal is used as the trigger source.
[KeyIn]
The key-in input is used as the trigger source.
[Max In]
This sets the signal with the largest value in a stereo channel or a multi-channel
component as the trigger source.
1–64
This sets the specified channel signal in a multi-channel component as the trigger
source.
e
[THRESHOLD] knob
Specifies the threshold level at which the limiter is applied.
f [ATTACK] knob
Specifies the attack time (the time from when the input signal exceeds the threshold until
the maximum limiter effect is reached).
g [RELEASE] knob
Specifies the release time (the time from when the input signal falls below the threshold
until the limiter effect is no longer applied).
h [OUTPUT] meter
Shows the output signal level.