User Manual

Table Of Contents
ProVisionaire Design DME7 Component Guide
67
and try the above procedure once again from step 1. In some cases, detection
will not occur correctly if the overall volume is raised excessively, or if the mics
and speakers are too close, or if sound from a speaker is directly entering a
mic.
The DME7 cannot detect multiple feedback points simultaneously. Slowly
increasing the fader and gain, etc. to allow the acoustic feedback to occur
gradually will allow for appropriate results to be obtained.
Control
Parameter types of the input/output values for each Port
Input Value
Control Parameter Output Value
Type Range
Input Port Name Parameter Range
Output Port Name Type Range
Value Num 0,1
Fixed On OFF:0, ON:1
Fixed On Value Num
OFF:0,
ON:1
Value Num 0,1
Dynamic On OFF:0, ON:1
Dynamic On Value Num
OFF:0,
ON:1