3 DC PARALLEL INPUT Connector
This connector is used to connect two PW800W units in
parallel. Two PW800W’s can be connected in this way to
ensure uninterrupted failsafe operation in the even that one unit
shuts down.
Use only the optional PSL120 Power Supply Link Cable for
this connection. Rotate the connector ring to the right to
connect, or to the left to disconnect.
4 AC IN Connector
Connect the included power cable here. First, connect the
power cord to the PW800W, then insert the power cord plug
into the AC outlet. Securely clamp the AC power cord using the
supplied cord clamp to prevent accidental disconnection from
the AC IN connector.
Be sure to use the included power cord. Use of other cords
may result in malfunction, heat generation, or fire.
To attach the cord clamp:
5 GROUND Screw Terminal
For maximum safety be sure to securely attach a confirmed
ground line to this terminal. The included power cable has a
three-pin plug, so the unit will be properly grounded if the AC
outlet used is grounded. If the AC outlet is not grounded be
sure to properly connect the GROUND terminal. Proper
grounding not only ensures safety, but it also guarantees
minimum noise from hum and interference.