User Manual

I/O devices and external head amps
V5 Reference Manual
177
This assigns the output signal from the AXT400 to the input channel, and at the same
time allows you to control and monitor the level of the AXT400 from the input channel.
Precautions
If the target device is unmounted, the parameters on the console return to their default
values. If a new device is mounted and patched, that devices parameters are applied to the
console.
All port assignments for a rack are defeated only if the status of the rack is NO ASSIGN.
Regarding the control of each developers device, control parameters are not stored in
scenes and saved in console files.
For devices that can set both Dante Input Patch and Port Assign, if Dante Input Patch has
already been set, the Port Assign setting will be ignored.
Using an external head amp
If an I/O card (such as an MY16-ES64 card) supports the remote protocol of an external head
amp in the QLs slot, you will be able to remotely control from the QL console some parameters
of the external head amp (Yamaha SB168-ES or AD8HR), such as phantom power (+48V)
on/off status, gain, and HPF.
For details on the I/O card settings, refer to the Owner’s Manual for the I/O card.
Connecting the QL series console to an AD8HR
To remotely control the AD8HR from the QL series console, install an MY16-ES64
EtherSound card in Slot 1 on the QL unit, then use an Ethernet cable to connect the QL unit
to the NAI48-ES. Then, connect the HA REMOTE connector on the NAI48-ES to the HA
REMOTE 1 connector on the AD8HR using an RS422 D-sub 9-pin cable. This connection
enables you to remotely control the AD8HR from the QL series console. To transmit audio
signals (input to the AD8HR) to the QL series console, connect the DIGITAL OUT A (or B)
connector on the AD8HR to the AES/EBU connector on the NAI48-ES using a D-sub 25-pin
AES/EBU cable. Signals will be sent or received between the NAI48-ES and the QL series
console via the MY16-ES64 card.
Alternatively, you can use a “daisy chain” connection to remotely control multiple AD8HR units
simultaneously. To do this, connect the AD8HRs HA REMOTE 2 connector to the second
AD8HRs HA REMOTE 1 connector. If you use the NAI48-ES, you can connect up to four
AD8HR units. Each slot of the QL series console provides up to 16 channels of input, so if you
want the audio signals from the AD8HR to be input to the QL series console, you’ll need to
install two MY16-EX cards in the console and connect the MY16-ES64 via an Ethernet cable.