The I/O field of the I/O DEVICE screen shows indicators for the status of the R-series units
and the Dante network.
For firmware that predates support for V1.60, the version indication will be yellow and the
indicator will be unlit.
Messages
Error, warning, and information messages are displayed.
Messages are also displayed in the Dante Controller Error Status field.
Each indicator lights or flashes as described below:
Error messages
The SYSTEM indicators will remain lit/blinking cyclically as follows until the problem has been
resolved.
If service is necessary, please contact the Yamaha service center listed in the QL5/QL1
Owner’s Manual.
No call-out Unlit
Lit The indicator remains lit steadily.
Blinking The indicator continues to flash.
Flash x2 The indicator flashes twice cyclically.
Flash x3 The indicator flashes three times cyclically.
[SYSTEM] indicators Meaning Possible solution
An internal error has occurred.
The device has failed. Contact
your Yamaha dealer for repair.
The MAC address setting has
been corrupted and no
communication can occur via
Dante.
The internal memory has
been corrupted.
If the problem persists after
setting START UP MODE back to
RESUME and turning the power
on again, consult your Yamaha
dealer.
UNIT ID is not unique.
Set a unique UNIT ID number for
the Dante network.
The DIP switches are not set
correctly.
Check the DIP switch settings,
and set them correctly.
Dante flow number limit was
exceeded.
Examine the Dante network
routing.
Flash x2
Flash x3
Flash x3
Lit
Lit
Blinking
Blinking
Lit