Fader level and meter display
This area displays the meter and fader for each channel.
1 Channel number
Indicates the channel number.
2 Σ clipping indicator
Lights to indicate that a signal is clipping at some point in the channel.
3 OVER indicator
Lights if the signal is clipping at the input section or output section of the channel.
4 Meter
Indicates the input or output level of the channel.
5 Fader
The channel level is indicated by the fader position and by a numeric value (in dB) that
appears immediately below the fader. If the channel's [ON] key is OFF, the fader turns
gray.
NOTE
Press any part of the meter area to assign the corresponding fader bank to the Channel Strip
section.
METERING POINT field
Select one of the following as the metering point at which the level will be detected. The
metering point for the level meter can be specified independently for input channels and
output channels.
For INPUT METER
PRE GC .................Immediately before GAIN
COMPENSATION
PRE D. GAIN .........Immediately before DIGITAL GAIN
POST D. GAIN.......Immediately after DIGITAL GAIN
PRE FADER...........Immediately before the fader (immediately before INPUT DELAY)
POST ON...............immediately after the [ON] key
For OUTPUT METER
PRE EQ .................Immediately before the EQ
PRE FADER...........Immediately before the fader
POST ON...............immediately after the [ON] key
PEAK HOLD button
Turn on this button to hold the peak level indication on each meter. Turn off this
button to clear the peak hold indication. PEAK HOLD button on/off operations
will affect both input channels and output channels. When you turn this button
off, the peak level indications that had been held will be cleared.
NOTE
You can also assign the PEAK HOLD button on/off function to a USER DEFINED key (page 208).
1
4
5
2
3
When the [ON] key for channel 7 is ON, and the [ON] key for
channel 8 is OFF