INSERT IN HA field
This field will appear if you have selected an input port (that features a head amp) as the
insert-in.
6 +48V button
Switches head amp phantom power (+48V) (currently-selected for insert 1 and insert 2)
on or off.
7 A.GAIN knob
Indicates the currently-selected head amp analog gain setting for insert 1 and insert 2.
You can use the [TOUCH AND TURN] knob to adjust the gain.
NOTE
If you have selected the INPUT jack on the QL console as
the input port for insert-in, make the HA settings in the
INSERT IN HA field.
Even if the INSERT ON/OFF button is OFF, the signal
selected for insert-out will continue to be sent.
8 HA meter
Displays the level of the currently-selected head amp input signal for insert 1 and insert
2.
9 Close button
Closes the screen.
INSERT screen (8ch)
1 Channel select button
Selects the channel to set. The channel icon, color, and number appear.
2 INSERT ON/OFF button
Switches the insert on or off. The currently-specified insert point setting appears above
the button.
3 INSERT OUT button
Displays the currently-selected port for insert 1 and insert 2. Press this button to open
the PORT SELECT window, in which you can select an output port.
4 INSERT IN button
Displays the currently-selected port for insert 1 and insert 2. Press this button to open
the PORT SELECT window, in which you can select an input port. You can also view the
insert-in level by checking the indicator located to the right of this button.
PORT SELECT window
Displayed when you press either the INSERT OUT or INSERT IN button in the one-channel
or the eight-channel INSERT/DIRECT OUT window. Set the input/output port used for
insertion.
1 Category select list
Selects the category of port. The categories correspond to the following ports. The
displayed categories vary depending on the channel type.
DANTE1–32........................... DANTE1–DANTE32
DANTE33–64......................... DANTE33–DANTE64 (QL5 only)
INPUT .................................... INPUT1–32 (QL5), INPUT1–16 (QL1) (input channels
only)
OUTPUT/DIGITAL ................. OMNI OUT1–16, DIGITAL OUT L/R (output channels
only)
SLOT1.................................... SLOT1(1)–SLOT1(16)
SLOT2.................................... SLOT2(1)–SLOT2(16)
3
4
3
2
1
4
1
2
3