User Manual

EQ and Dynamics
Reference Manual
63
A KEY IN SOURCE select button
Press this button to display the KEY IN SOURCE SELECT window, in which you can select
a key-in signal that will trigger the dynamics.
SELF PRE EQ ....................... The pre-EQ signal of the same channel.
SELF POST EQ..................... The post-EQ signal of the same channel.
MIX OUT 13–16 ..................... Output signals of MIX channels 13–16
CH1–64 POST EQ (QL5), CH1–32 POST EQ (QL1), ST IN1L–8R POST EQ,
MIX1–16 POST EQ, MTRX1–8 POST EQ, ST L/R, MONO POST EQ
........................ The post-EQ signal of the corresponding channel
*1
*1. The selectable signals are limited to the corresponding eight-channel group.
NOTE
In the case of QL1, channels that do not exist on the model will not be shown.
B KEY IN FILTER parameter area (Displayed only for Dynamics 1 for an input
channel)
Enables you to make various settings for a filter that lets the key-in signal pass.
Filter select buttons ............. Select the type of filter from HPF, BPF, or LPF. To
disable the filter, press the button that is turned on.
Q knob................................... Indicates the filter Q. You can use the [TOUCH AND
TURN] knob to adjust the value.
FREQUENCY knob ............... Indicates the filter cutoff frequency. You can use the
[TOUCH AND TURN] knob to adjust the value.
C KEY IN CUE button (Displayed only for Dynamics 1 for an input channel)
Enables you to cue-monitor the signal that has been selected as the KEY IN SOURCE
signal. Cue will be canceled if you have selected a dynamics type that does not feature
this button, or if you move to a different screen.
NOTE
The cue monitoring does not support CUE B.
D Tabs
Use these tabs to select a channel that you want to view on the screen.
DYNAMICS1/2 window (8ch)
This window displays the input channel or output channel dynamics settings in groups of 8
channels simultaneously. This window is convenient if you want to adjust the threshold or
certain other parameters while watching the adjacent channels to the left and the right.
1 Channel select button
Selects the channel that you want to control. The current channel icon and number
appear on the button, and the channel name appears immediately below the button.
2 DYNAMICS OUTPUT meters, GR meter
Indicate the output levels of signals after dynamics processing, and the amount of gain
reduction. If GATE is selected as the dynamics type, a three-step indicator appears,
indicating the open/close status of the gate.
If GATE is selected as the dynamics type, the indicator status means the following:
Gate status
Red Yellow Green Off (dark)
On/Off status On On On Off
Open/Close
status
Close Open Open
Amount of gain
reduction
30 dB or more less than 30 dB 0 dB
1
2
4
5
3
Type = Any type other than GATE
Type = GATE