User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- MIDI Data Format
- Input/Output Specifications
- Electrical characteristics
- Mixer Basic Parameters
- Pin Assignment Chart
- MIDI Implementation Chart
Scene memory
Reference Manual
93
Using the Focus Recall function
“Focus Recall” is a function that lets you specify the scene parameters that will be recalled
(loaded) when you recall a scene. You can specify these settings for each scene. This function
is useful if you want to recall only the input channel settings of a specific scene.
NOTE
In contrast to Focus, the QL series console also features a “Recall Safe” function that enables
you to exclude specific channels and parameters from recall operations. However, while the
Focus Recall function is specified individually for each scene, the Recall Safe settings are applied
to all scenes.
NOTE
• The FOCUS field enables you to make settings for the Focus function. The buttons in this field
correspond to the scene list shown on the left side of the SCENE LIST window.
• Scenes for which Focus settings are made are indicated by a “FOCUS” indication in the STATUS
field of the SCENE LIST window.
• You can use the Focus function in conjunction with the Recall Safe function. Channels or
parameters that are excluded from Recall operations by either Focus or Recall Safe will not be
recalled.
• For FOCUS RECALL, the NAME parameter is included in the DCA indicator.
SCENE LIST window
1 FOCUS button
Enables or disables the Focus function for each scene.
2 SET popup button
Press this button to access the FOCUS RECALL popup window, which allows you to
select the parameters that will be subject to recall.
3 FOCUS PARAMETER indicators
These indicators show the focus recall settings that are specified for each scene.
4 CURRENT SETTING field
Specifies the content that will be saved by the next scene store operation.
STEP
1. Press the SCENE field in the Function Access Area.
2. Press the FOCUS tab at the bottom of the SCENE LIST window.
3. In the SCENE LIST window, press the SET button for the scene you want to set.
4. Follow the procedure starting with step 3 in the “Using the Recall Safe function” on
page 70 to make settings.
5. Recall a scene for which you have made Focus Recall settings.
SCENE field SCENE LIST window
1 2
3
4