User Manual

QL Editor Owner’s Manual
35
When the receiver is on and not connected via a ShowLink
®
remote control
When the receiver is off
2 D.GAIN (Digital Gain)
Drag the knob in the screen to adjust the digital gain (input gain) of the input channel.
3 HPF (High Pass Filter)
Use the [ON] button at the right to switch the high-pass filter on/off. You can use the knob at left to adjust the cutoff
frequency. The current value is shown in the numerical box below the knob. An indication of “H” will appear on the
EQ graph of the equalizer.
4 GC (Gain Compensation)
This is an on/off switch for the head amps analog gain correction. This function maintains a specific level for the audio
signal on the network when the same I/O rack or built-in head amp of the QL unit are being shared by multiple QL/CL
series units. This button will be displayed only if the DANTE or INPUT ports have been patched.
5 A.GAIN-D.GAIN Link
This is an on/off switch for linking the analog gain and digital gain when gain compensation is on.
6 Ø (Phase)
Inverts the phase polarity of the signal after AD conversion.
7 HPF Type
Switches the attenuation (per octave) of the high pass filter between –12dB/oct and –6dB/oct.
(Example) Indication of signal quality meter
8 Signal quality meter
Displays the quality of the received RF signal. The vertical axis represents quality, and the horizontal axis represents
time. The meter indicates the condition of the connection. It is refreshed once per second. The height of the meter bar
graph will be reduced if the RF signal quality deteriorates due to movement away from the transmitter or radio wave
interference.
8