User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Warning/Error Messages
- Index
- Data List
- Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- MIDI Data Format
- Input/Output Specifications
- Electrical characteristics
- Mixer Basic Parameters
- Pin Assignment Chart
- MIDI Implementation Chart
I/O devices and external head amps
Reference Manual
158
Remotely controlling an external head amp
An external head amp (“external HA”) connected via MY16-ES64 or NAI48-ES can be
remotely controlled from the QL series console. For details on how to connect a QL series
console with an external head amp, refer to “Using an external head amp” on page 156 and
the external head amp’s operating manual.
I/O DEVICE screen (EXTERNAL HA page)
1 EXTERNAL HA field
Shows the state of the connected external HA.
2 ID/Model name/+48V master
This displays information for the external HA mounted in the rack. The ID number is
automatically assigned in order of the connected devices from 1 to 4. This field also
enables you to view the on/off status of the master phantom power.
3 Virtual racks
These are up to four racks in which remotely controllable external HA units can be
mounted. If an external HA is mounted, this field will indicate the HA settings (GAIN
setting, and on/off status of the phantom power and HPF). Press a rack to open the
EXTERNAL HA window for that rack.
4 EXTERNAL HA PORT SELECT button
Press this button to display the HA PORT SELECT window, in which you can set the input
port for the external head amp mounted in the rack.
NOTE
If an external HA is connected to one of the slots on the QL series console, you must specify an
appropriate input port manually. If this is set incorrectly, the external HA will not be detected
correctly when you patch input ports to input channels.
STEP
1. Connect the QL series console to an external HA.
2. In the function access area, press the RACK button.
3. Press the EXTERNAL HA tab in the upper part of the I/O DEVICE screen.
4. Press the EXTERNAL HA PORT SELECT button for the corresponding rack in the I/O
DEVICE screen (EXTERNAL HA page).
5. Use the PORT SELECT buttons in the EXTERNAL HA PORT SELECT window to select
the input ports to which the audio output of the external HA is connected.
6. Press the CLOSE button to close the EXTERNAL HA PORT SELECT window.
7. In the I/O DEVICE screen (EXTERNAL HA page), press the rack in which the external
HA you want to control is mounted.
8. Remotely control the external head amp in the EXTERNAL HA window.
VIRTUAL RACK screen
(EXTERNAL HA page)
2 3 4
1
5 6