User Manual

Channel Job
Reference Manual
67
NOTE
Simply selecting a parameter in step 4 does not enable Recall Safe. To turn Recall Safe on or off,
you must also perform the operation described in step 5.
Bus settings are not subject to Recall Safe. They will always be reproduced in the recalled scene.
This means that if Recall Safe is enabled for one of several channels included in a link group or
one of two channels set to stereo, the parameter settings of that channel may differ from those of
the other channel(s). In such cases, the applicable parameter will be automatically re-linked the
next time it is operated.
You can globally apply Recall Safe to channel links by using the global parameter.
You can use the Recall Safe function along with the Focus Recall function (page 88). Channels
or parameters that are excluded from Recall operations by either Focus or Recall Safe will not be
recalled.
If you hold down the [SEL] key while performing a recall operation, all parameters of that channel
will be treated as Recall Safe regardless of the state of the SAFE PARAMETER SELECT
selections.
RECALL SAFE MODE window
1 CLEAR ALL button/SET ALL button
The CLEAR ALL button turns off (disables) the Recall Safe function (that is currently set
for individual channels) and the Global Recall Safe function simultaneously. The SET ALL
button turns on (enables) these functions simultaneously.
NOTE
The parameters that would be affected by the Recall Safe function will not change.
2 CH RECALL SAFE field
Indicates the channels currently specified to Recall Safe function.
3 SET BY SEL button
Enables you to use the [SEL] keys on the panel to select channels that will be affected by
the Recall Safe function. Turn this button on, and then press the [SEL] key for the
channel to which you want to apply Recall Safe. Recall Safe will turn on. Press the same
[SEL] key once again to de-select the channel.
4 GLOBAL RECALL SAFE display field
Indicates the state of Recall Safe settings that are not made in units of channels, and the
Recall Safe settings for racks. Press this field to open the GLOBAL RECALL SAFE window.
These buttons correspond to the following parameters.
NOTE
If a dual-type GEQ rack or Premium rack has been selected, you can apply Recall Safe to rack
A and B individually. For other racks, the setting for racks A and B will be linked.
1
3
5
9
2 4
6
7 0A 8
IN PU T PAT C H
All input channel patching (including INSERT IN/OUT and DIRECT OUT
patching)
INPUT NAME All input channel names, icons, and channel colors
OUTPUT PATCH All output channel patching (including INSERT IN/OUT patching)
OUTPUT NAME All output channel names, icons, and channel colors
HA All I/O devices, and HA-related parameters for external head amps
CH LINK All channel link group settings
MUTE GROUP
NAME
Name of the mute group
CUSTOM FADER
BANK
Custom fader bank settings
GEQ RACK
EFFECT RACK
PREMIUM RACK
Apply Recall Safe to GEQ racks 1–16, Effect racks 1–8, Premium racks 1–8
individually.
FADER BANK
SELECT
FADER BANK selections, GAIN/PAN/ASSIGN knob selection status (set in
units of blocks)
PORT TO PORT HA PORT TO PORT settings
PORT TO PORT
PATC H
PORT TO PORT patching
All parameters are affected by Recall Safe on these channels.
Some parameters are affected by Recall Safe on these channels.
Recall Safe has been canceled on these channels.