manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
MIDI
V5 Reference Manual
189
MIDI/GPI screen (CONTROL CHANGE page)
You can specify how Control Changes will be transmitted and received, and specify the event
(fader/knob operation, [ON] key on/off operation, etc.) assigned to each control number.
1 CONTROL CHANGE field
Enables you to switch Control Change transmission/reception on or off, and specify
whether Control Changes will be echoed out. This setting is linked with the CONTROL
CHANGE field on the MIDI SETUP page.
• Tx button ............................... Switches control change transmission on/off.
• Rx button............................... Switches control change reception on/off.
• ECHO button......................... Selects whether incoming control changes will be
echoed out from the MIDI transmit port.
2 CONTROL CHANGE MODE field
This field enables you to select the Control Change transmission/reception mode. This
setting is linked with the CONTROL CHANGE MODE field on the MIDI SETUP page.
• NRPN mode (when the NRPN button is on):
Various mix parameters on the QL series console will be transmitted and received on a
single MIDI channel as NRPN messages. If you select this mode, the assignments in the
list will be ignored.
• TABLE mode (when the TABLE button is on):
Various mix parameters on the QL series console will be transmitted and received on a
single MIDI channel as Control Change messages, according to the assignments in the
list.
NOTE
The channel on which Control Changes are transmitted and received is specified by the PORT/
CH field on the MIDI SETUP page (page 184).
3 List
Shows the event (fader/knob operation, [ON] key on/off operation, etc.) assigned to
each control number.
• NO..........................This indicates the control number. You can use control numbers
1–31, 33–95, and 102–119.
• CONTROL CHANGE EVENT
.........................Indicates and enables you to select the type of event assigned to
each control number. When you press an event, the MIDI
CONTROL CHANGE window will appear, allowing you to change
the control number assignment.
4 CLEAR ALL button
Press this button to clear all event assignments on the list.
5 INITIALIZE ALL button
Press this button to restore all event assignments on the list to their default state.
6 Scroll knob
Scrolls the contents of the list. You can use the [TOUCH AND TURN] knob to operate
this.
1
6
4
5
2
3