manual
Setup
V5 Reference Manual
238
•DCA 9-16
The following parameters related to DCA 9 to 16 will be linked.
•DCA 9 - 16 level
• DCA 9 - 16 on/off
• DCA 9 - 16 cue
• DCA 9 - 16 DCA MUTE TARGET (DCA group mute targets)
NOTE
Even if the cue mode is LAST CUE, the cue for the target DCA will come on at the same time
for consoles linked by cascade connections.
•MUTE MASTER
Links ON/OFF for mute masters.
NOTE
The settings of Dimmer function are not linked. Make these settings individually on each
console.
• SENDS ON FADER
Links SENDS ON FADER behavior.
• SENDS ON FADER mode
• The send destination bus
• CUE
The following cue-related parameters and events will be linked.
• Cue enable/disable
• Cue mode (MIX CUE or LAST CUE, 5.1 SOLO)
NOTE
Regarding 5.1 SOLO, no links are made if the console at the cascade destination is set to
Stereo mode.
• Cue point settings for input channels and output channels
• SOLO MUTE
NOTE
Solo operation is used for all cascaded consoles (MASTER and SLAVE).
•OTHERS
The following parameters will be linked.
• Scene recall operations
• Scene store operations
• Edit scene titles
• DIMMER (MONITOR window) operations
• Panel LED and display brightness (SETUP window) operations
3 CASCADE COMM PORT buttons
Specify the communication port used for transmitting and receiving link information
when operations such as cue and scene store/recall are linked between cascade-
connected QL series consoles.
• NONE.....................No link operation
• MIDI .......................Use MIDI port
• SLOT1....................Use SLOT1
4 Tabs
Switches between pages (CASCADE IN PATCH, CASCADE IN ATT, and CASCADE OUT
PATCH).
PORT SELECT window
Press the OUT PATCH button to open this window.
1 Category select list
Selects the port (slot 1–2) that will be shown on the screen.
2 Port select buttons
Within the specified slot, these buttons select the ports that will be patched.
2
1