manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Warning/Error Messages
- Index
- Data List
- Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- MIDI Data Format
- Input/Output Specifications
- Electrical characteristics
- Mixer Basic Parameters
- Pin Assignment Chart
- MIDI Implementation Chart
Graphic EQ, Parametric EQ, effects, and Premium Rack
Reference Manual
148
Using the graphic EQ, parametric EQ, effect, and
Premium Rack libraries
GEQ/PEQ library
Use the “GEQ library” or “PEQ library” to store and recall GEQ and PEQ settings. All GEQ
and PEQ units used in the QL series console can use this GEQ library or PEQ library.
Although are two types, 31BandGEQ and Flex15GEQ in the GEQ library, you are free to recall
items between differing types. However, only 31BandGEQ settings that use less than fifteen
bands can be recalled to a Flex15GEQ.
200 items can be recalled from the library. Number 000 is a read-only preset, and the
remaining library numbers can be freely read or written.
To recall an item from the GEQ library, press the LIBRARY button located at the top of the
GEQ EDIT window.
Similarly, to recall an item from the PEQ library, press the LIBRARY button located at the top
of the PEQ EDIT window.
NOTE
• Store and recall operations are performed on individual GEQ units. For one rack, you can store
and recall two Flex15GEQ or 8BandPEQ units independently as A and B.
• To access the GEQ EDIT window or the PEQ EDIT window, press the rack container in the GEQ
field.
Effect library
Use the “Effect library” to store and recall effect settings. 199 items can be recalled from the
effect library. Numbers 001–027 are read-only presets. The remaining library numbers can be
freely read or written.
To recall an item from the effect library, press the LIBRARY button located at the top of the
EFFECT EDIT window.
NOTE
If you recall an effect whose effect type is COMP276, COMP276S, COMP260, COMP260S,
EQUALIZER610, OPENDECK, M.BAND DYNA., or M.BAND COMP, the other effects may be
momentarily muted in some cases.
Premium Rack library
For the Premium Rack, there are seven library items for each module type. You’ll use the
library of the module type to store and recall Premium Rack settings. The libraries are
numbered 000–100, and 000 is read-only data for initialization. All library items other than
#000 can be freely read and written.
To recall an item from the Premium Rack library, press the LIBRARY button located at the top
of the window for the corresponding Premium Rack.