manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- MIDI Data Format
- Input/Output Specifications
- Electrical characteristics
- Mixer Basic Parameters
- Pin Assignment Chart
- MIDI Implementation Chart
I/O devices and external head amps
Reference Manual
161
Remotely controlling an R series unit
This section explains how to remotely control an R series unit that’s connected to the Dante
connector.
I/O DEVICE screen (I/O page)
1 Display switch buttons
Press one of these buttons to view the corresponding I/O device. If you press and hold
down this button, all LEDs of the corresponding I/O device will blink.
For more information about VIRTUAL/CONFLICT/DUPLICATE displayed below this
button, refer to
1 on page 158, “I/O device list.”
2 ID/Model name display
This shows the ID number, model name, and version of the I/O device.
If the WITH RECALL button is turned ON in the REMOTE HA SELECT screen, “w/RECALL”
is displayed. If the +48V MASTER switch for the mounted device is turned ON,“+48V
MASTER” is displayed.
3 DANTE SETUP button
Press this button to open the DANTE SETUP window, in which you can make settings
for the audio network.
4 SYSTEM/SYNC indicators
Error, warning, and information messages are displayed. Refer to the list (page 244) for
detailed information about messages.
HA display
This shows the HA settings of the I/O device. Press this area to open the I/O DEVICE HA
window, in which you can make detailed head amp settings.
If you press the [SEL] key of an input channel, the corresponding port will light. (It does not
light for external QL series consoles.)
5 Analog GAIN knob
Indicates the analog gain setting. This screen is only for display; the value cannot be
edited.
6 +48V indicator
Indicates the phantom power (+48V) on/off status for each port.
7 OVER indicator
Warns you when the input signal is clipping.
8 HPF indicator
Indicates the high-pass filter on or off status for each port.
STEP
1. In the upper part of the I/O DEVICE screen, press the I/O tab to display the I/O
DEVICE screen (I/O page).
2. Press the rack in which the I/O device that has head amp functionality is mounted.
3. Open the I/O DEVICE HA screen to remotely control the head amp of the I/O device.
4. To remotely control a head amp from an input channel, press a knob in the
SELECTED CHANNEL section to display the SELECTED CHANNEL VIEW screen.
5. Press the GAIN/PATCH field of the channel you want to adjust. The GAIN/PATCH
window will appear.
6. Control the head amp of the I/O device in the GAIN/PATCH window.
7. When you have finished making settings, press the “x” symbol to close the window.
8. Press the rack in which the I/O device on the OUTPUT side is mounted.
9. Set the output port on the OUTPUT PATCH window, as necessary.
Refer to step 7 in “I/O device patching”on page 158.
1 2
4
3
6
8
5
7