manual

I/O devices and external head amps
Reference Manual
174
Remotely controlling an external HA from the input channels on a QL
series console
You will be able to use the external HA in the same way as the head amp on an I/O device or
on the QL console. For details on the GAIN/PATCH window, refer to “Making HA (Head Amp)
settings” on page 28.
Controlling an internal head amp
Control the internal head amps (“internal HA”) in QL series consoles. It is not necessary to
change the input patch.
INTERNAL HA window
1 +48V MASTER
Indicates the master phantom power on or off status.
2 +48V button
These switch phantom power on/off for each channel.
3 A. GAIN knob
These indicate the gain of the internal HA. To adjust the value, press the knob to select
it, and then use the [TOUCH AND TURN] knob. The level meter located at the
immediate right of the knob indicates the input level for the corresponding port.
4 GC button
Switches on or off the Gain Compensation function that maintains a consistent signal
level on the audio network.
5 Displayed port switch tabs
These tabs switch the port that is displayed in the INTERNAL HA window
STEP
1. Use the Bank Select keys and the [SEL] key to access the SELECTED CHANNEL VIEW
screen that includes the channel for the head amp that you want to control.
2. Press the GAIN/PATCH field of the channel whose external HA you want to adjust.
3. Press the PATCH button in the GAIN/PATCH window, and select the input port
assigned to the external HA.
4. Remotely control the external head amp in the GAIN/PATCH window.
STEP
1. Press the INTERNAL HA tab in the upper part of the I/O DEVICE window.
2. Set the output port on the INTERNAL HA window, as necessary.
SELECTED
CHANNEL VIEW
screen
GAIN/PATCH window
I/O DEVICE screen (INTERNAL HA page)
2
4
3
5
1