manual

Channel Job
Reference Manual
72
NOTE
If a dual-type GEQ rack or Premium rack has been selected, you can apply Recall Safe to rack
A and B individually. For other racks, the setting for racks A and B will be linked.
5 Channel select button
Selects the channel for which you want to set the Recall Safe function.
NOTE
Switching channels using this button will not affect the channel selection on the top panel.
6 Selected channel display
This area indicates the icon, number, color, and name of the currently-selected channel.
7 APPLY TO ALL INPUT button (input channels only)
Turn on this button to apply the Recall Safe parameter selection for one input channel
to all other input channels.
Turn this on if you want to apply Recall Safe to the same parameters for all input
channels.
8 APPLY TO ALL OUTPUT button (shown only for output channels)
Turn on this button to apply Recall Safe parameter selection for one output channel to
all other output channels.
Turn this on if you want to apply Recall Safe to the same parameters for all output
channels.
9 SAFE PARAMETER SELECT field (excluding DCA groups)
Selects Recall Safe parameters for the selected channel.
The button indication varies depending on the channel type.
Input channel
NOTE
ST IN channels do not feature INSERT, INSERT PATCH, and DIRECT OUT button.
MIX channel
MATRIX channel
STEREO channel
MONO channel
If Recall Safe is turned on for global parameters, the safe parameter select buttons of the
selected channel will light green, as follows.
In this illustration, the items that are lit green indicate that the INPUT PATCH, INSERT
PATCH, and DIRECT OUT parameters have been set to Safe by the INPUT PATCH Global
parameter settings.
In the same way, turning on the Global parameters INPUT NAME, OUTPUT PATCH, and
OUTPUT NAME will cause the corresponding safe parameters of each channel to light
green. On-screen buttons and corresponding parameters apply to the following
channels:
OTHERs
CH LINK All channel link group settings
MUTE GROUP
NAME
All Mute group names
FADER BANK
SELECT
FADER BANK selection status, MASTER FADER assign
status
Button name Corresponding parameter
Input
channel
MIX
channel
MATRIX
channel
STEREO/
MONO
channel
WITH MIX SEND Send level to the MIX bus O
WITH MATRIX
SEND
Send level to MATRIX bus
O
ALL
*1
All parameters O O O O
HA HA-related settings O
HPF HPF settings O
EQ EQ settings OOOO