Owner`s manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Warning/Error Messages
- Index
- Data List
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- MIDI Data Format
- Input/Output Specifications
- Electrical characteristics
- Mixer Basic Parameters
- Pin Assignment Chart
- MIDI Implementation Chart
Channel Job
Reference Manual
62
2 CH RECALL SAFE field
Indicates the channels currently specified to Recall Safe function.
3 SET BY SEL button
Enables you to use the [SEL] keys on the panel to select channels that will be affected by
the Recall Safe function. Turn this button on, and then press the [SEL] key for the
channel to which you want to apply Recall Safe. Recall Safe will turn on. Press the same
[SEL] key once again to de-select the channel.
4 GLOBAL RECALL SAFE display field
Indicates the state of Recall Safe settings that are not made in units of channels, and the
Recall Safe settings for racks. Press this field to open the GLOBAL RECALL SAFE window.
These buttons correspond to the following parameters.
NOTE
If a dual-type GEQ rack or Premium rack has been selected, you can apply Recall Safe to rack
A and B individually. For other racks, the setting for racks A and B will be linked.
5 Channel select button
Selects the channel for which you want to set the Recall Safe function.
NOTE
Switching channels using this button will not affect the channel selection on the top panel.
6 Selected channel display
This area indicates the icon, number, color, and name of the currently-selected channel.
7 APPLY TO ALL INPUT button (input channels only)
Turn on this button to apply the Recall Safe parameter selection for one input channel
to all other input channels.
Turn this on if you want to apply Recall Safe to the same parameters for all input
channels.
8 APPLY TO ALL OUTPUT button (shown only for output channels)
Turn on this button to apply Recall Safe parameter selection for one output channel to
all other output channels.
Turn this on if you want to apply Recall Safe to the same parameters for all output
channels.
9 SAFE PARAMETER SELECT field (excluding DCA groups)
Selects Recall Safe parameters for the selected channel.
The button indication varies depending on the channel type.
• Input channel
NOTE
ST IN channels do not feature INSERT, INSERT PATCH, and DIRECT OUT button.
• MIX channel
• MATRIX channel
• STEREO channel
I N PU T PAT C H
All input channel patching (including INSERT IN/OUT and DIRECT OUT
patching)
INPUT NAME All input channel names, icons, and channel colors
OUTPUT PATCH All output channel patching (including INSERT IN/OUT patching)
OUTPUT NAME All output channel names, icons, and channel colors
HA All I/O devices, and HA-related parameters for external head amps
CH LINK All channel link group settings
MUTE GROUP
NAME
Name of the mute group
CUSTOM FADER
BANK
Custom fader bank settings
GEQ RACK
EFFECT RACK
PREMIUM RACK
Apply Recall Safe to GEQ racks 1–16, Effect racks 1–8, Premium racks 1–8
individually.
FADER BANK
SELECT
FADER BANK selections, GAIN/PAN/ASSIGN knob selection status (set in
units of blocks)
PORT TO PORT HA PORT TO PORT settings
PORT TO PORT
PAT C H
PORT TO PORT patching
All parameters are affected by Recall Safe on these channels.
Some parameters are affected by Recall Safe on these channels.
Recall Safe has been canceled on these channels.