Status bar
The status bar at the right edge of the display shows icons to indicate the status of the Rio-D2 unit.
Icon
Six types of icons are shown.
The displayed position depends on the icon.
About HA Read Only
This function allows the HA parameters to be changed only from a supported digital mixer such as a RIVAGE PM, CL
or QL series device. When the HA Read Only is ON, it will not be possible to turn off the settings of the HA parameters
or HA Read Only from this device.
Also, this function is set when this device synchronizes with a supported digital mixer, or when this device is operated
after the synchronization. Once HA Read Only is turned to ON, even if the connection between this device and the
supported digital mixer is interrupted, the HA Read Only setting is maintained until this device is restarted.
NOTE
The settings in the SETUP menu of this device can be changed even when HA Read Only is ON.
In order to turn HA Read Only OFF, you must perform an operation from the supported digital mixer, or power-cycle this unit.
Upper line
Shows the ERROR icon or the INFORMATION icon .
If both ERROR and INFORMATION have occurred, the ERROR icon takes priority and is shown.
If neither ERROR nor INFORMATION has occurred, nothing is displayed.
If ERROR or INFORMATION have occurred, the content is shown in the second line of the status display area
within each HA screen. For an explanation of the content, refer to “Messages” (page28).
Middle line
Shows the MUTE icon if muted (all ports together).
If the SECONDARY PORT parameter is set to DAISY CHAIN, the DAISY CHAIN icon is shown.
If muted (all ports together) and in addition the SECONDARY PORT parameter is set to DAISY CHAIN, the
MUTE icon takes priority and is shown.
If mute is cleared (all ports together) and in addition the SECONDARY PORT parameter is set to
REDUNDANT, nothing is displayed.
Lower line
Shows the LOCK status.
If panel lock is enabled, the PANEL LOCK icon is shown.
If HA Read Only is specified, the HA READ ONLY icon is shown to indicate read-only.
If panel lock is enabled and HA Read Only is specified, the PANEL LOCK icon takes priority and is shown.
If panel lock is not enabled, or if HA Read Only is not specified, nothing is displayed.
ERROR INFORMATION MUTE PANEL LOCKDAISY CHAIN