14.7.7. "Recall Filter" dialog box
Click on [Recall Filter] in the "Presets" area of the device sheet to open this.
Here you can specify which parameters will be recalled when you recall a preset. For example if the input/output
levels do not change for any of the presets, you can exclude the INPUT LEVEL and OUTPUT LEVEL from recall, so
that the level settings can stay the same without your having to re-specify the levels for each preset.
[All On] button
Turns on (blue) all of the buttons. All parameters will be recalled.
[All Off] button
Turns off (white) all of the buttons. None of the parameters will be recalled.
Parameter select buttons
[HA] button
If this is on, the HA gain and phantom power (+48V) settings of the input ports will be recalled.
[IN PATCH] button
If this is on, the input patch settings and input channel names will be recalled.
These buttons include patching to the MY4-AEC input channels From Far-end, Farend Voice, Near-end
Mic., Near-end Voice, and To Far-end.
[INPUT]/[LEVEL] button
If the [INPUT] button is on, the following input channel settings will be recalled.
Input channelsPhase, HPF, Digital Gain, PEQ, COMP, GATE, AGC, FBS, Insert on/off
Insert on/off is only for the MTX5-D.
Stereo input channelsDigital Gain, PEQ, AGC, COMP
If the [LEVEL] button is on, the input channel level and on/off (mute) settings will be recalled.
These can be specified individually for each channel.
In the “MTX Configuration” dialog box, if [INPUT PORT SETUP] is changed from “MONO x2” to
“STEREO,” the settings of the [INPUT]/[LEVEL] buttons will follow the “L” side.
14. Audio Processors : MTX5-D/MTX3