User Manual

[Test - On]/[Test – Off] button
ProVisionaire Design will directly transmit commands specified in the “Controlled Device” table in
numerical order. If [1shot] has been selected in the [Command Type] list box, the [Test - Off] button will be
disabled.
You can execute command transmission on-line or off-line.
“Controlled Device” table
Specify information for the device that will receive commands. When the device receives a trigger signal,
it will transmit commands in numerical order, as shown in the table.
For details on settings for the receiving device, refer to the documentation for the corresponding device
regarding commands.
[Protocol] list box
Select the protocol supported by the device that receives the commands.
[IP Address] text box
Specify the IP address of the device that receives commands.
[Port No.] text box
Specify the port number of the device that receives commands.
[Comments] text box
You can enter up to 32 bytes of text. This text could be a device name that would help you identify
the device.
[Copy] button
Copies the information for the selected command specified in the “Controlled Device” table and
Command text box to the copy buffer.
[Paste] button
Pastes (and overwrites) the information from the copy buffer into the “Controlled Device” table and
Command text box.
[Test] button
ProVisionaire Design will directly transmit commands that are entered in the Command text box.
[Overwrite] / [Insert] button
Click this button repeatedly to toggle between Overwrite and Insert. While the [Insert] button is displayed,
you can insert a hexadecimal number at the beginning or in the middle of the text in the Command text
box.
Command text box
If [On/Off] has been selected in the [Event Mode] list box, repeatedly pressing the button on an external
device, such as a DCP unit, will cause the MTX to transmit the On command and Off command
alternately. If [1shot] has been selected in the [Event Mode] list box, repeatedly pressing the button on an
external device, such as a DCP unit, will cause the MTX/MRX to transmit the programmed commands.
Commands should be hexadecimal numbers, and entered in the format of XX.
If a command for controlling an external device is expressed by a text string in the relevant specification
document, use the Converter area to convert the text string into a hexadecimal number.
The maximum command length is 128 bytes.
[Converter>>] button
Displays an area where you can convert a text string into a hexadecimal number.
[ASCII to Hex]/[Hex to ASCII] option button
Select whether you want to convert a text string to a hexadecimal number or vice versa.
14. Audio Processors : MTX5-D/MTX3
ProVisionaire Design User Guide | 201