User Manual

Table Of Contents
Apéndices
Manual de referencia
249
2 SYSTEM REALTIME MESSAGE
2.1 SONG SELECT (F3)
Reception
Select the track number shown in the TITLE LIST screen of the USB memory recorder.
2.2 TIMING CLOCK (F8)
Reception
This message is used to control effects. This message is transmitted twenty-four times
per quarter note.
Echoing of this message depends on the OTHER item in the ECHO settings.
2.3 ACTIVE SENSING (FE)
Reception
Once this message has been received, MIDI communication will be initialized (e.g.,
Running Status will be cleared) if no message is received for an interval of 400 ms.
This message is not subject to echoing.
2.4 SYSTEM RESET (FF)
Reception
When this message is received, MIDI communication will be initialized (e.g., Running
Status will be cleared).
This message is not subject to echoing.
3 SYSTEM EXCLUSIVE MESSAGE
3.1 MMC
< MMC STOP >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and stops.
< MMC PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
< MMC DEFERED PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
< MMC RECORD STROBE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts
recording.
< MMC PAUSE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses.
3.2 BULK DUMP
This message is used to send or receive the contents of various memories stored within
the unit.
The basic format is as follows.
The CL series uses the following data types for a bulk dump.
*1) 0–300 Scene Number (0 Request Only),
*2) 1–199 Input EQ Library Number (1–40 Request Only)
*3) 1–199 Output EQ Library Number (1–3 Request Only)
*4) 1–199 Dynamics Library Number (1–41 Request Only)
*5) 0–199 GEQ Library Number (0 Request Only)
*6) 1–199 Effect Library Number (1–27 Request Only)
*7) 512–583 Input 1-72,
*8) 584–599 STIN 1L-8R,
*9) 768–791 MIX 1-24,
*10) 1024–1031 MATRIX 1-8,
*11) 1280–1282 STEREO L-C,
*12) 512–530 GEQ 1-19, 531–538 EFFECT GEQ 1-8,
*13) 512–519 EFFECT 1-8,
*14) 512 Current Data,
*15) 768 Current Data with Recall Safe,
*16) 8192 Store Undo Data, 8193 Recall Undo Data, 8194 Clear Undo Data,
*17) 0–199 Input CH Library Number (0 Request Only),
*18) 0–199 Output CH Library Number (0 Request Only),
*19) 512–527 Premium Rack 1A, 1B, 2A, … 8A, 8B
*20) 0–100 Each Premium Effect Library Number (0 Request Only)
*21) 1536–1607 Input 1-72 (for Dynamics2),
*22) 1608–1623 STIN 1L-8R (for Dunamics2),
*23) 0-10 Dante Input Patch Library Number (0 Request Only)
Data is lost when you write to the preset library.
The unique header (Model ID) identifies whether the device is a CL series.
To calculate the check sum, add the bytes starting with the byte after BYTE COUNT
(LOW) and ending with the byte before CHECK SUM, take the binary complement,
and set bit 7 to 0.
CHECK SUM = (-sum)&0x7F
Bulk Dumps can be received at any time, and can be transmitted at any time when a
Bulk Dump Request is received.
A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump
Request.
In the data portion, seven words of 8-bit data are converted into eight words of 7-bit
data.
STATUS 11110011 F3
Song select
Song number 0sssssss ss
Song number (0-127)
STATUS 11111000 F8
Timing clock
STATUS 11111110 FE
Active sensing
STATUS 11111111 FF
System reset
STATUS 11110000 F0
System exclusive message
ID No. 01111111 7F
Real time System exclusive
Device ID 0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND 00000110 06
Machine Control Command(MCC) sub-id
00000001 01
Stop(MCS)
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01111111 7F
Real time System exclusive
Device ID 0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND 00000110 06
Machine Control Command(MCC) sub-id
00000010 02
Play(MCS)
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01111111 7F
Real time System exclusive
Device ID 0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND 00000110 06
Machine Control Command(MCC) sub-id
00000011 03
Deferred Play(MCS)
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01111111 7F
Real time System exclusive
Device ID 0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND 00000110 06
Machine Control Command(MCC) sub-id
00000110 06
Record strobe
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01111111 7F
Real time System exclusive
Device ID 0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND 00000110 06
Machine Control Command(MCC) sub-id
00001001 09
Pause(MCS)
EOX 11110111 F7
End of exclusive
Command rx/tx Function
F0 43 0n 3E cc cc 19 mm … mm dd
dd … ee F7
rx/tx
BULK DUMP DATA
F0 43 2n 3E 19 mm … mm dd dd F7 rx
BULK DUMP REQUEST
Module Name(mm) Data Number(dd)
SCENE LIB “SCENE___” *1) *14) *15) *16)
INPUT EQ LIB “INEQ____” *2) *7) *8)
OUTPUT EQ LIB “OUTEQ___” *3) *9) *10) *11)
Dynamics LIB “DYNA____” *4) *7) *8) *9) *10) *11) *21) *22)
INPUT CH LIB “INCHNNL_” *17) *7) *8)
OUTPUT CH LIB “OUTCHNNL” *18) *9) *10) *11)
GEQ LIB “GEQ_____” *5) *12)
EFFECT LIB “EFFECT__” *6) *13)
Premium Effect “PEFFECT_” *19)
Portico5033 LIB “P5033___” *20)
Portico5043 LIB “P5043___” *20)
U76 LIB “U76_____” *20)
Opt-2A LIB “OPT-2A__” *20)
EQP-1A LIB “EQ-1A___” *20)
DynamicEQ LIB “DYNAEQ__” *20)
Dante Input Patch LIB “DANTEIN_” *23)
Mixer Setup “MIXERSET” Fix (512)
Outport Setup “OUT_PORT” Fix (512)
Monitor Setup “MONITOR_” Fix (512)
MIDI Setup “MIDI_SET” Fix (512)
Lib Number “LIB_NUM_” Fix (512)
Program Change Table “PRGMCHG_” Fix (512)
Control Change Table “CTRLCHG_” Fix (512)
Preference (Current) “PREF_CUR” Fix (512)
Preference (Admin) “PREF_ADM” Fix (512)
Preference (Guest) “PREF_GST” Fix (512)
User Defined Keys (Current) “UDEF_CUR” Fix (512) include Knob, Encoder
User Defined Keys (Admin) “UDEF_ADM” Fix (512) include Knob, Encoder
User Defined Keys (Guest) “UDEF_GST” Fix (512) include Knob, Encoder
Custom Fader Bank (Current) “CFAD_CUR” Fix (512)
Custom Fader Bank (Admin) “CFAD_ADM” Fix (512)
Custom Fader Bank (Guest) “CFAD_GST Fix (512)
User Level (Current) “UKEY_CUR” Fix (512)
User Level (Guest) “UKEY_GST” Fix (512)
Module Name(mm) Data Number(dd)