User Manual

English
Messages
Owner’s Manual
19
Warning Messages
The indicators will light and/or flash as shown until the
cause is resolved.
If the green [SYNC] indicator is unlit, the units clock is
unconfirmed.
If the green indicator is flashing, the unit is the clock
master.
If the green indicator is lit, the unit is the clock slave and the
clock is synchronized.
Information Messages
The indicators will remain lit and/or flashing cyclically to
report the status.
If the orange [SYNC] indicator is unlit, the unit is operating
normally.
If the green [SYNC] indicator is unlit, the unit's clock is
unconfirmed.
SYNC Indicators Description Possible Solution
The word clock is not
set correctly.
Set the clock mas-
ter and sampling
frequency correctly
on the Ri8-D/
Ro8-D-native
device or in Dante
Controller.
Dante Network circuit
is broken.
Make sure that the
Ethernet cables are
not removed or
short-circuited.
Other Dante-compatible
devices cannot be
found due to an
incorrectly-wired Dante
Network.
Make sure that the
Ethernet cables are
connected cor-
rectly.
SYNC Indicators Description Possible Solution
A non-GbE-compatible
device is connected.
When transferring
audio via Dante,
use device that
supports GbE.
The [SECONDARY]
connector has taken
over communications
during redundant
network operation.
Check the circuit
connected to the
[PRIMARY]
connector.
An abnormality has
occurred on the circuit
connected to the
[SECONDARY]
connector during
redundant network
operation.
Check the circuit
connected to the
[SECONDARY]
connector.
Flash
Flash x2
Flash x3
LightLight
or
flash
FlashLight
or
flash
Flash x2Light
or
flash
SYNC Indicators Description Explanation
Synchronizing on a
Dante network
Please wait until
started has
completed or until
the unit has finished
synchronization.
It may take up to 45
seconds for
completion.
Waiting to receive
setting data
If START UP
MODE is set to
REFRESH on the
R-series unit, the
input/output will be
muted until the unit
receives setting
data after it starts
up.
The unit is functioning
correctly as the word
clock master.
The unit is operat-
ing as the word
clock master.
The unit is functioning
correctly as the word
clock slave.
The unit is
operating as the
clock slave and the
clock is
synchronized.
Light
Flash
Light