Syncing the unit to a MADI input signal
NOTE
If the unit acts as the clock follower on the Dante network, input
to the unit the same MADI clock used for the device that is the
clock leader. You can use Dante Controller (available from the
following website) to check which device is the current clock
leader.
http://www.yamahaproaudio.com/
Using an external clock on MADI-compatible
devices, and syncing the unit to a different
external clock:
NOTE
The same external clock supplied to MADI-compatible
devices must be input to [WCLK IN FOR SRC] on the unit.
If the unit acts as the clock follower on the Dante network,
input to the unit the same external clock used for the device
that is the clock leader. You can use Dante Controller
(available from the following website) to check which device
is the current clock leader.
http://www.yamahaproaudio.com/
Displaying the MADI Input
and Output Signals
The frame format and number of channels for the MADI
input signal or output signal are displayed in the MADI
[STATUS] area.
Use the MADI [STATUS] INPUT/OUTPUT key to switch
between the input signal display and the output signal
display.
Remote Control
RMio64-D can be remotely controlled from the NUAGE
Workgroup Manager and R Remote.
You can use the NUAGE Workgroup Manager to
configure items that cannot be configured from the unit’s
panel, such as individual settings for MADI SRC input/
output controls and setting the MADI output to a different
format than the MADI input.
NOTE
For the latest information about remote control compatible
devices, refer to the Yamaha Pro Audio website:
http://www.yamahaproaudio.com/
Remote Controllable/
Displayable Parameters
Control from NUAGE
Workgroup Manager
When RMio64-D is operating in the NUAGE Workgroup,
you can use remote control to configure the RMio64-D
and use direct monitoring functions.
Word Clock Source Input Clock Source Output Clock Source
DANTE
MADI
WCLK IN
DANTE MADI
Clock
WCLK IN
(FOR SRC)
MADI IN
Same as
Input Clock Source
Same as Word
Clock Source
Signal Processing
Signal
SRC
SRC
Word Clock Source Input Clock Source Output Clock Source
DANTE
MADI
WCLK IN
DANTE MADI
Clock
WCLK IN
(FOR SRC)
MADI IN
Same as
Input Clock Source
Same as Word
Clock Source
Signal Processing
Signal
SRC
SRC
Parameter Description NUAGE
Work-
group
Manager
R
Remote
SRC ON/OFF Turns MADI SRC on or off.
SRC INPUT
CLOCK
SOURCE
For selecting the MADI SRC
clock source: the MADI input
signal or the clock input from
the WCLK IN FOR SRC
connector.

SRC OUTPUT
CLOCK
SOURCE
For selecting the MADI SRC
clock output: the input signal
or the unit’s leader clock.
INPUT RATE Displays the frequency when
the MADI input signal is
automatically detected as
44.1 kHz or 48 kHz.
For selecting 1Fs, 2Fs, or
4Fs in combination with the
MADI input rate.

STATUS
INPUT
Displays the status of the
MADI input signal.

STATUS
OUTPUT
Displays the status of the
MADI output signal. You can
also make changes to the
frame format and number of
channels for the MADI
output signal.

BNC AES/
EBU OUT
For selecting the Dante input
channel output from the
[SYSTEM LINK OUT]
connector as the AES/EBU
signal.
CLOCK For selecting the source
used as the leader clock.

PANEL LOCK Locks the panel to prevent
operation of the unit’s
controllers. Default settings
are turned off.