14.11. Parameter Link Group Area
Creates a parameter link group to link multiple parameters for Level-type or for ON/OFF-type.
A single parameter can be registered in multiple parameter link groups. The created parameter link group can be
used in Snapshot, Scheduler, GPI, DCP, MCP1, or the Remote Control Setup List. Level-type and ON/OFF-type
cannot be mixed in a single parameter link group. Up to 64 parameter link groups can be created.
The following methods are available for registering to a parameter link group.
[Parameter]
Registration Source Registration Method
Component Editor While holding the < Ctrl > key down, drag & drop the parameter into
the green area of the Settings dialog.
Right-click the parameter and select the parameter link group to
register in [Add to Parameter Link Group].
Parameters Area*1 Drag & drop the parameter into the green area of the Settings
dialog.
Right-click the parameter and select the parameter link group to
register in [Add to Parameter Link Group].
*1. Multiple parameters can be registered to a parameter link group simultaneously by pressing < Shift > and <
Ctrl > together.
Pressing any letter key while selecting a parameter link group or other item in the Parameter
Link Group area will select the parameter link group or other item with the matching first
letter.
[New] Button
Creates a parameter link group.
[Delete] Button
Deletes the selected parameter link group or parameter.