[Open] Button
Displays the Link Control editor for the selected parameter link group.
14.11.1. Link Control Editor
There is a link control for each parameter link group. When a link control is changed, the parameters registered in
the parameter link group are also changed at the same time.
Even if the parameters registered in the parameter link group are changed, the link control parameters do not
change.
Link control can be assigned to GPI/DCP/Remote Control Setup List/Parameter Link Group/MCP1.
The name of the parameter link group is displayed in the title bar.
Level-type ON/OFF-type
Fader (level-type only)
Sets values for level-type parameters.
[ON] Button (ON/OFF-type only)
Sets values for on/off-type parameters.
[Match Values] Button
If [Absolute] or [Equal] is selected in the combo box, the value of the registered parameter will be the
same as the value of the link control.
[Active] Button
If this is on, the parameter link group is enabled. Turn this off if you want to temporarily disable the link.
Combo Box
Set how the level-type and ON/OFF-type settings are applied.
[Absolute]/[Equal] Sets the value of the registered parameter to the same value as
the link control.
[Relative]/[Opposite] When you operate the link control, the registered parameters will
move while maintaining their relative positions.