User Manual

Table Of Contents
14.16.2. Remote Control Setup List Dialog
Click [Remote Control Setup List] from the [Tools] button in the device sheet to open this dialog.
The MRX7-D can be controlled from an external device using the Dante [PRIMARY]/[SECONDARY] terminal or the
[RS-232C] terminal.
To control or monitor from an external device, parameters, meters, snapshots, and snapshot groups must be
registered in the Remote Control Setup List.
Configure the external device according to the "MTX3 MTX5-D MRX7-D XMV Series EXi8 EXo8
Remote Control Protocol Specifications."
Remote Setup Tab
Two methods are available for registering to the list.
Registration Source Registration Method
Design Sheet While holding the < Ctrl > key down, drag & drop the component
into the list.
Right-click the component and select [Add to Remote Control List].
Component Editor/
Parameter Setting Window
[Parameters]
While holding the < Ctrl > key down, drag & drop the parameter into
the list.
Right-click the parameter and select [Add to Remote Control List].
[Components]
Right-click a location outside the parameter and select [Add to
Remote Control List].
Parameters Area*1
Drag & drop components or parameters into the list.
Right-click a component or parameter and select [Add to Remote
Control List].
Parameter Sets Area
Drag & drop snapshots into the list.
Drag & drop snapshot groups into the list.
14. Audio Processor MRX7-D
206 | ProVisionaire Design V1.2 User Guide