User Manual

Table Of Contents
[Nominal]
Here you can make settings for the Nominal function.
By specifying the nominal value, you can assign a specific LED position as the normal volume setting. For
example by specifying the center LED as the volume setting for normal use and setting the maximum
value to the maximum volume that is allowable for the system, you can prevent damage to the system
that might occur if the volume of the background music were raised during a noisy time.
If the check box is selected, the Nominal function will be on.
[Nominal Value] specifies the nominal value.
[Nominal LED Position] specifies the LED position that will light when the level reaches the nominal value.
If the check box is cleared (Nominal function off), both parameters will be grayedout and unavailable.
[Sensitivity] list box
Sets the sensitivity of parameter changes in response to the rotary operation of the DCP knob.
If [Acceleration] is on, the parameter will change faster if the knob is rotated more rapidly. If [Fast]
is selected as the [Sensitivity], the [Acceleration] setting is dimmed and unavailable.
[MTX Source Select]
For usage, refer to [MTX Source Select] in the DCP component: Settings dialog (switch).
For parameters, refer to [MTX Level / MTX Send Level].
[Dimmer & Lock] tab
This sets the brightness of the LEDs on the DCP unit and the settings for the resting state.
27. DCP
ProVisionaire Design V1.2 User Guide | 385