User Manual

Table Of Contents
15.4. Direct Set Button
Changes the device parameter to the value specified in [Press Value].
You can assign up to 16 parameters for the same device or multiple devices.
Control
Property Value
[Control]
Click the [...] button to open the “Target Editor” dialog box.
You can check/edit the assigned parameters.
[Press Value]
Sets the value to be set on the device.
When multiple parameters are assigned, check/change them in the
“Target Editor” dialog box.
The dialog box opens when you click the […] button under Control.
[Indicator Mode] When Stateful is selected, the indicator lights up when the device is at the
specified value.
When you click the Direct Set Button, the parameter value set in Press Value under Properties is sent to the
device.
If the sent parameter value matches the value of the controlled device, the button lights up in the color specified
by On Color. If the values do not match, the button lights up in the color set by Off Color.
By placing multiple Direct Set Buttons, you can achieve radio button-like behavior.
Specifically, these buttons are suitable for controlling the Router and Source Selector parameters of MTX3,
MTX5-D, MRX7-D, and DME7.
The following shows a specific example.
Place a Direct Set Button and set Indicator Mode in Properties to Stateful.
Place multiple buttons with these same settings.
Assign Ch 1 to all buttons from Router > Patch.
15. Widgets
60 | ProVisionaire Control PLUS V1.0 User Guide