❺ [Register Device] button
Each time you click it, a device is added. Set the IP address of the device on the network and the target model.
❻ [Date Time Display Format]
Specify the display time format used in the [Fault & Event List].
❼ [Database Size Limit]
When the database size exceeds the specified size, the oldest data will be automatically deleted.
Advanced settings
❽ [TCP port number for ProVisionaire Edge HTTP server (default value: 50081)]
Set a TCP port number through which to pass monitoring information to other computers.
When you change the TCP port number, change the Windows firewall settings as well.
❾ [TCP port number with which ProVisionaire Edge collects IoT data from devices (default value: 50080)]
Set a TCP port number through which to collect monitoring information.
When you change the TCP port number, change the Windows firewall settings as well.
3.1.2. About screen
You can check the statuses of the server services that configure the operation of ProVisionaire Edge.
3. Screen structure
ProVisionaire Edge V1.2 User Guide | 9