User Manual
Table Of Contents
Supported devices (as of ProVisionaire Edge V1.2)
Device name Connector IP address IP address setting method
DM7 Series *1 NETWORK connector Any
SETUP → NETWORK → FOR MIXER
CONTROL
DM3 Series *2 NETWORK connector Any
SETUP → NETWORK → FOR MIXER
CONTROL
RIVAGE PM Series
(console, DSP) *3
NETWORK [PC] connector 192.168.53.*
(fixed)
The address cannot be changed.
CL/QL Series *4 NETWORK connector Any
SETUP → NETWORK → FOR MIXER
CONTROL
Rio-D2 Series Dante Primary connector Any
SETUP → IP ADDRESS
DME7 *4 NETWORK connector Any
Settings → IP Settings → DME Control
Port
MRX7-D, MTX5-D Dante Primary connector Any Set the address using a UNIT ID and DIP
switch (192.168.0.xxx). Alternatively, you
can set any address using MTX-MRX
Editor.
MTX3 *4 NETWORK connector Any Set the address using a UNIT ID and DIP
switch (192.168.0.xxx). Alternatively, you
can set any address using MTX-MRX
Editor.
PC-D Series NETWORK connector Any
NETWORK → CONTROL
XMV Series *4 NETWORK connector Any Set the address using a UNIT ID and DIP
switch (192.168.0. xxx). Alternatively,
you can set any address using Amp
Editor.
XMV-D Series Dante Primary connector Any Set the address using a UNIT ID
(192.168.0.xxx). Alternatively, you can
set any address using Amp Editor.
NEXO NXAMPmk2 Series
*5
Expansion slot connector Any REMOTE CONTROL SETTINGS
DZR/DXS-D Series Dante Primary connector Any
UTILITY → NETWORK
*1 DM7 Control is not automatically detected. Specify the IP address using Manual IP.
*2 When connecting two or more DM3 Standard units, specify the IP address using Manual IP.
*3 To avoid problems with control communications that use the NETWORK [PC] connector of the RIVAGE PM
series, we recommend using a network interface dedicated to the RIVAGE PM series. Connect other devices to a
different network interface.
*4 For devices connected via NETWORK connectors, we recommend using a network interface separate from the
Dante network, wherever possible. This measure can avoid placing a communication load on the NETWORK
connector. Connect the devices connected via Dante connectors to a different network interface.
*5 When monitoring the NXAMPmkII series, use the NXRM104 or NXAE104 card.
2. Basic process
6 | ProVisionaire Edge V1.2 User Guide