User Manual

R Remote Version 5.9 Users Guide 36
Checkbox
Selects the device firmware (Model) and/or the Dante firmware with each device to be updated.
For devices with a Dante module that are displayed as Not Available in Dante firmware in the Firmware
Info (file information area), the check boxes are grayed out because the model firmware cannot be
updated.
[Update] button
Starts the update process.
In Rio3224-D2 and Rio1608-D2, the change correspondence of the board is implemented by V1.80 or
later of the main body firmware (Model). Therefore, if the version is V1.80 or later, it may not be possible
to downgrade to a lower version., and under that condition, the check box cannot be selected. In that
case, after pressing the [Update] button, a message will be displayed stating that the downgrade cannot
be performed.
Tio1608-D2 cannot be downgraded below V2.0. After pressing the [Update] button, a message will be
displayed stating that the downgrade cannot be performed.
[Cancel] button
Stops the update operation of the device that has not been updated yet.
Update operation
This section describes how to update the firmware.
1.
Start R Remote. Choose “Tool” “Firmware Update” from the menu of R Remote.
2. (In the case of RMio64-D) Quit the NUAGE Workgroup Manager it it is running.
3. Press the “Select” button and select the firmwarexxxx_v*_**_rrmt.bin” to be updated.
Devices that can be updated appear in the device information area.
Firmware files can be downloaded from the following website:
https://www.yamahaproaudio.com/
The characters “xxxxrepresent the product name and *_**represents the firmware version
number (e.g., “rio3224-d_v4_10_rrmt.bin”).
When you select an old firmware which is not supported by R Remote, “invalid file” appears and
the update cannot be started.
If the firmware of the device is an older version than the firmware file, the checkbox for its device
will be automatically checked.