User Manual

Table Of Contents
3.3.2. ”Button” component editor (dB)
When the button is switched on, the value set in is output, and when the button is switched off,
the value set in is output.
② −∞ to 10.00
③ −∞ to 10.00
Parameter types of the input/output values for each Port
Operation Output Value
Input Port
Name
Trigger/Proces
sing
Output Port
Name
Type Range
On1 Trigger: Button On1 Value dB ∞–10.00
Num -20000–20000
* It is also possible to control the ON button by inputting OFF:0 and ON:1 in the Value (Num) data
type for the Input Port.
3. Control Components
126 | ProVisionaire Design Component Guide