User Manual

Table Of Contents
3.17. Processing (Value): Multi Compare
This component compares the input values from multiple ports and detects the channel number with
the largest/smallest input value.
Greatest or Smallest can be selected in the dialog that is displayed when the component is placed.
(For 2 inputs)
INPUT
1: Input value 1 (–20,000 to 20,000), (∞ to 10.00)
2: Input value 2 (–20,000 to 20,000), (∞ to 10.00)
OUTPUT
Out 1: Outputs ON:1 when the channel 1 input value is the largest/smallest value. Outputs 0 for all
other cases.
Out 2: Outputs ON:1 when the channel 2 input value is the largest/smallest value. Outputs 0 for all
other cases.
3.17.1. “Multi Compare” component editor
Input signals can be checked.
Threshold value
Displays the result (channels with the largest/smallest input values) of comparing multiple input
values that exceed the Threshold value.
3.17.2. “Multi Compare” component editor (Greatest)
Compares input values greater than the Threshold value and outputs 1 from the channel determined to
have the largest value. All other channels output 0.
3.17.3. “Multi Compare” component editor (Smallest)
Compares input values smaller than the Threshold value and outputs 1 from the channel determined to
have the smallest value. All other channels output 0.
3. Control Components
148 | ProVisionaire Design Component Guide