User Manual

Table Of Contents
3.18. Processing (Value): Difference
This component is used to obtain the difference between two input values.
INPUT
1: Input value 1 (–20,000 to 20,000), (∞ to 10.00)
2: Input value 2 (–20,000 to 20,000), (∞ to 10.00)
OUTPUT
Out: The value of input 1 minus input 2
If the result of subtracting input value 2 from input value 1 is negative (minus), the result is 0.00.
3.18.1. “Difference” component editor
Input signals can be checked.
Displays the value of subtracting input value 2 from input value 1.
Parameter types of the input/output values for each Port
Input Value Operation Output Value
Type Range Input
Port
Name
Trigger/P
rocessing
Output
Port
Name
Type Range
Value Num -20000–2
0000
CH
(1,2)
Processin
g:
Differenc
e
- - - -
dB ∞–10.00 - - - -
- - - - Out Value Num -20000–2
0000
- - - - dB ∞–10.00
3. Control Components
150 | ProVisionaire Design Component Guide