If the input is above the Threshold value and below –18 dB, the output is set to –18 dB. If the input is
above the Threshold value and above –18 dB, the output level is adjusted by the Ratio value.
If the noise gate is on, the volume is adjusted so that input and output are the same level at –60 dB,
and then adjusted so that the output is –18 dB when it reaches the Threshold value.
If the input is above the Threshold value and below –18 dB, the output is set to –18 dB.
If the input is above the Threshold value and above –18 dB, the output level is adjusted by the Ratio
value.
AGC [ON] button
Switches the AGC function between enabled and disabled.
[INPUT] level meter
Shows the input signal level.
[COMPENSATION LEVEL] knob
Specifies the amount of gain compensation. Higher settings will produce more compensation. Please
note that it might not be possible to maintain a constant output level if this value is changed
suddenly.
[RESPONSE TIME] knob
Specifies the response speed for gain compensation. This applies to compensation that raises the gain;
it is the time required for a 6 dB increase. It does not affect compensation that lowers the gain.
NOISE GATE [ON] button
Switches the noise gate between enabled and disabled.
[OUTPUT] level meter
Shows the compensated output signal level.