[HOLD] knob
Specifies the hold time (the time from when the input signal falls below the THRESHOLD until
attenuation begins to be removed).
[RELEASE] knob
Specifies the release time (the time from when the hold time specified by the [HOLD] knob has
elapsed until Ducker is no longer applied). The setting is expressed as the time required for the level to
change 6 dB.
[OUT] meter
Shows the output signal level.
2.13.2. Control
Parameter types of the input/output values for each Port
Input Value Control Parameter Output Value
Type Range Input
Port
Name
Paramete
r Range
Output
Port
Name
Type Range
Value Num 0,1 On
OFF:0,
ON:1
On Value Num
OFF:0,
ON:1
2. Audio Components