When the key-in signal is not detected, the output level is attenuated, and when the key-in
signal is detected, the output level is returned to the original level.
The normal attenuation level is set using RANGE. The operating output level is 0 dB.
[ATTACK] knob
Configures the time it takes to reach the target output level after detecting the key-in signal.
[RANGE] knob
Sets the level of attenuation. If the MODE is concave, this is the attenuation level when the key-in
signal is detected, and if the MODE is convex, this is the normal level when the key-in signal is not
detected.
[RELEASE] knob
Sets the amount of time it takes for the output level to return to its original level or attenuate after
the key-in signal falls below the threshold and the HOLD TIME has elapsed.
[BYPASS] button
Bypasses the attenuation effect.
[OUTPUT] meter
Shows the output signal level.